Huawei SUN2000 description
HUAWEI SUN2000-17KTL-M2 inverter for commercial PV systems
HUAWEI SUN2000-17KTL-M2, 3 - more phase PV-Inverter
-
The SUN2000-17KTL-M2 inverter is a three-phase, grid-tied inverter for PV strings that converts the DC power generated by the PV strings into AC power and feeds it into the grid.
-
The component has RS485 communication for data exchange with the Smart Power Meter. Commissioning is made much easier by the Huawei FusionSolar app so that it can be successfully completed in just a few minutes.
-
The inverter is also equipped with overvoltage protection (type 2 for AC and DC), as well as two independent MPP trackers. The pleasantly quiet operating noise is also positive: natural convection is sufficient for cooling. The Huawei SUN2000-12KTL-M2 inverter has a rated power of 12.000 watts,, the voltage range is from 160 to 950 volts. The European efficiency is specified at 98,5% .
- Active safety: AI-assisted Arc Detection (AFCI).
- Increased yields: Up to 30% more energy with optimizers.
-
FusionAPP: APP for full control
- Flex communication: WiFi, Fast Ethernet, 4G
Mini Power (New Power GmbH) is an official distributor of HUAWEI in Europe and is committed to selling Huawei's original SUN Inverter series products.
Question answer - Huawei SUN2000
Do these inverters come directly from the Huawei?
What's in the package if I order?
Is this inverter High Current Version?Is high current important?
The only difference between the normal Huawei inverter and the HC inverter is the maximum input power. Current per MPPT:
Normal (our products): 11A
High Current: 13,5A
It's rare to get above 11A and the normal version would be sufficient in most situations. For example, modules with a maximum current (Imp) of 12,98A, 99% of the time it will not exceed 11A.
But if you have modules much more than 13A, HC version can be better.
Is this inverter intended for commercial use?
These inverters are equipped with multiple MPPTs, and PLC / MBUS communication (2000KTL-A, 2KTL, and 6KTL-M2000 in conjunction with Smartlogger2A6).
Do you have inverters intended for commercial use?
These inverters are equipped with multiple MPPTs, and PLC / MBUS communication (33KTL-A, 36KTL, and 60KTL-M0 in conjunction with Smartlogger3000A03).
What is PLC / MBUS?
What is the difference between PLC / MBUS and RS485 communication?
For communication via RS485, the inverters (slaves) are connected in a row to the last inverter (master) connected to the SmartLogger (2-wire connection).