The current shop ratings are loaded directly from the official rating source.
- 1,6 kWh storage capacity in the set– Size of the offered storage configuration
- 250W nominal power– Performance limit of the offered version
- Solarbank 2 compatibility– Check compatibility before ordering
- Balcony assembly / use– For assembly selection and installation planning
- 1 × Anker SOLIX Solarbank 2 E1600 Pro (SKU 10002)
- 2× RENEPV N-TOPCon flexible PV module set 2×250W (SKU 35100)
- 1 × Anker SOLIX Smart Meter (SKU 10101)
Anker SOLIX Solarbank 2 E1600 Pro storage units, 4 x 250W flexible solar panels, 1.6 kWh set
Technical details & expansion
- 1,6 kWh storage capacity in the setSize of the offered storage configuration
- 250W · Rated powerPerformance limit of the offered version
- Solarbank 2 · CompatibilityCheck compatibility before ordering
- Balcony · Installation / UseFor mounting selection and installation planning
Pay securely and easily
Up to 30 years warranty
Enjoy maximum peace of mind: up to 30 years warranty on high-performance modules, 10–12 years product warranty on inverters and 10 years on battery storage systems (with a 15-year service life). For other products, please refer to the specific product documentation.
30-day returns
Orders from Mini Power can be returned within 30 days of receipt when the return conditions are met. Statutory cancellation rights remain unaffected.
View cancellation policy24/7 customer support
You can contact us 24 hours a day, 7 days a week. We respond as quickly as possible during the applicable service hours; an immediate round-the-clock response is not promised.
Contact servicePickup in Weilheim
Pickup discount: 4% on all other orders. For battery storage units weighing at least 40 kg or battery-and-solar-panel sets: 3% plus EUR 70 per battery or set. Each unit or set is counted once.
Pickup address: Mini Power warehouse (New Power GmbH)
Paradeisstr. 83, 82362 Weilheim in Oberbayern, Germany.
Solar panels and mounting structures can only be collected in Weilheim.
Pickup hours (Mon–Fri):
09:00–15:00 without an appointment.
15:00 p.m.–18:00 p.m. by prior appointment only.
Contact & appointments: info@miniminipower.com
Dynamic delivery estimateDelivery
Delivery time: currently unavailable
This estimate is based on the maintained delivery mode. The checkout display remains authoritative.Estimate confirmed at checkoutReal customer reviews from Mini Power
Mini Power / New Power GmbH has been in operation since 2025 Anker SOLIX Authorized Retailer certified. Proof is in the official Anker SOLIX Dealer overview visible.

Product description
The Anker SOLIX Solarbank 2 E1600 Pro Set with 4× RENEPV V3.0 250W flex modules Combines 1,6 kWh storage, smart meter, and 1000 W module power. The modules are designated RFMM10NH6-250. Scope of delivery and datasheet values have been updated; connection, wiring, and permissible input limits must be checked against both manufacturers' documentation before commissioning.
Mini Power / New Power GmbH has been in operation since 2025 Anker SOLIX Authorized Retailer certified. Proof is in the official Anker SOLIX Dealer overview visible.
Package contents
1 x Anker Smart meter
4 x RENEPV Flexible Solar Module 250W
8 x Anker SOLIX Solar panel extension cable (3m)
1 x Anker SOLIX Schuko AC cable (5m)
4 x Y-cables for solar panels (2 pairs)
1 x wrench for removing MC4 connectors
2 x L-shape wall mount
2 x cable organizer
48 × fastening straps / connectors
Produktvorteile
-- 1000 W updated module power: Four modules, each with 250 W, result in the module output specified in the set, which is uniformly documented.
-- Unique model assignment: The RFMM10NH6-250 is specified uniformly in terms of scope of delivery, datasheet and technical specifications.
-- 1,6 kWh storage capacity: The storage capacity is shown separately from the PV module power output.
-- Connection accessories listed: Smart meter, extension cable, AC cable and Y-cable remain traceable within the set.
Compatibility
The set configuration is not a blanket approval for every wiring configuration or installation situation. Before commissioning, the MPP voltage, MPP current, open-circuit voltage, short-circuit current, number of inputs, current and power limits, and connectors must be checked against the documentation of the storage or inverter manufacturer and the RENEPV datasheet.
Technical information
-- Main unit: Anker SOLIX Solarbank 2 E1600 Pro
-- RENEPV modules in a set: 4 × 250 W = 1000 W
-- Model: RFMM10NH6-250
-- Power tolerance: 0 to +5 W
-- Module efficiency: 21,4%
-- Vmp/Imp: 36,98V/6,76A
-- Voc / Isc: 43,35V ±3% / 7,30A ±3%
-- Dimensions per module: 1.159 × 1.009 × 2,5 mm
-- Weight per module: 4,3 kg ±3%
-- Construction: PET front and back layers, black backing
-- Junction box: IP67
-- PV cable: 4,0 mm²
-- Connectors: MC4-compatible, IP67
-- Operating temperature: −20 to +65 °C
-- Maximum series fuse: 15 A
-- Maximum system voltage: 1.500 V DC
-- Warranty according to data sheet: 5-year product warranty and 25-year performance warranty
RENEPV RFMM10NH6-250 Datasheet (PDF, English)
Matching accessories and related products
- Anker Solix Storage
- Anker SOLIX Solarbank 2 E1600 Pro storage units, 8 × 250W flexible solar panels, 1,6 kWh
Why Mini Power
For Mini Power become in Set with 4× RENEPV V3.0 250W flex modules Storage system or microinverter, 1000 W module power, and accessories are shown separately. The current manufacturer's datasheet is linked directly; the confirmed scope of delivery is listed completely and in the original order. Since the electrical limits of both product groups must be tested together, the page does not contain a general compatibility guarantee or freely transferable wiring recommendations. This ensures that product selection remains transparent and technically comprehensible.
Frequently asked questions
-- What module power output does the updated set contain?
Included are 4 RENEPV modules, each with 250 W, for a total nominal power of 1000 W.
-- What fasteners or connecting parts are included?
Included are only the fastening or connecting parts listed in the scope of delivery, in the quantity specified therein.
Is electrical compatibility automatically guaranteed?
No. The electrical limits and the specific wiring must be checked against both manufacturers' documentation before commissioning.
Savings potential with a complete set
Product values follow your selection; check example and household values.
Indicative estimate.
Custom power or capacity: adjust investment. Reset restores product values.
Grid output only: no charging or off-grid output rating.
More assumptionsMore assumptions
Loading estimate.
Complete all fields and check allowed ranges.
Whole-system savings
estimated in year 1
per month on average
Self-consumption + export payments. Include all purchase costs for payback.
Indicative estimate.
All results
- PV generation
- kWh / year
- Self-consumption
- kWh / year
- Payback
- years
- total investment
Self-consumption rate whole system:
Average savings / year · 20 years
per month on averageSavings over 20 years
Less investmentPrice change / yield reduction: / .
How this estimate is calculated
PV generation before storage losses and AC limits. Model yield for northern, central and southern Germany is 920 / 1,020 / 1,150 kWh per kWp per year, adjusted for orientation, tilt and shade. Seasonal weights, daylight and synthetic weather distribute generation across 8,760 hours, with peaks capped at module power. Each hour is split equally into four quarter-hours for energy dispatch. No measured weather data is used.
A reference household profile derived from meter data represents consumption in 35,040 quarter-hours and retains the load peaks present in those intervals. Day and night values are scaled separately to your annual consumption and chosen daytime share (08:00–18:00). Solar supplies current demand first, followed by stored energy. AC and charging power limit energy delivered in each 15-minute interval. Only energy delivered to the household counts as self-consumption. All comparisons use identical weather and consumption profiles.
Mini Power planning assumption: self-consumption × 1.20 (+20%). The scenario is capped by PV generation, annual demand and AC output; it is not a measured efficiency improvement or a yield guarantee.
Reference load profile source, primary data by CoSSMic / ISC Konstanz: Open Power System Data (2020), Household Data, 2020-04-15 · CC BY 4.0 License. Adaptation: household residential5, year 2017; cumulative meter readings converted to 15-minute consumption and scaled to annual demand and daytime share. Fixed Central European Time (UTC+1). This is a reference household, not a measurement of your consumption.
Assumptions: 90% of nominal capacity is usable; charging and discharging together have 90% round-trip efficiency. Storage starts empty. Remaining energy carries across days and years but counts as savings only when used. With DC coupling, PV surplus can charge before the AC limit; with AC coupling, PV is first limited to the AC rating entered. Direct use, battery discharge and export share that AC limit. No grid charging or battery export.
Whole system, first year: the value of self-used solar electricity at the electricity price entered, plus payment for exported surplus.
For every comparison, yield and use are recalculated in each of the 20 years. Annual PV yield falls linearly with the module aging assumption, while electricity prices change annually on a compound basis. The export payment stays constant. Total savings add up all annual values, including negative values; average annual savings are this total divided by 20. The net value deducts the investment including extra costs. Payback is reached when cumulative savings cover this investment. The point within a year is interpolated linearly.
The single AC input is a shared model limit; separate PV and battery inverters need a more detailed calculation. Unless charging power is provided separately, available PV and free storage capacity limit charging. The scaled reference household and synthetic PV weather do not replace measurements of your installation. Peaks shorter than 15 minutes, battery aging, standby use, control behavior, installation losses and specific heat-pump or electric-car loads are not fully represented. Replacements, maintenance, financing and discounting are excluded. Higher AC power or greater storage increase savings only when surplus and later consumption can use them. Savings are not guaranteed.
Model estimate, no yield guarantee. Monthly figure = annual average; seasonal variation applies.
V
Data sheet & instructions
Verified product-specific documents and instructions.
Technical information
Why Mini Power
Mini Power We support you in selecting balcony power plants, storage systems, solar panels, and suitable accessories. Product information, scope of delivery, and compatibility are presented clearly so you can choose a system that suits your location and energy needs. If you have any questions, you can contact us directly at info@miniminipower.com.
Start with Mini Power into your own energy transition.
Come these Anker Solarbank 2 E1600 Pro directly from Anker?
How does the whole thing work? Solarbank 2 E1600 Pro Systems?
Muss die Anker Solarbank 2 E1600 Pro with the WLAN network and the AnkerBe connected to the app?
What precautions should I take before installing extended batteries?
Can the Solarbank E1600 with the Solarbank Can two E1600 Pro/Plus work?
Can the Solarbank E1600 for capacity expansion with an extension battery for the Solarbank Can two E1600 Pro/Plus units be connected?
Can I Solarbank Connect 2 E1600 Pro units to one battery via cable?
What are the most important specifications of the Solarbank 2 E1600 Pro?
If the internal inverter of Solarbank If my two E1600 Plus inverters are defective, can I use an external inverter to fix the problem?
Does it work? Solarbank 2 E1600 Pro with only 1, 2 or 3 connected MPPTs?
Is this set the right storage solution for you?
Compare storage technology and expandability independent of modules, mounting material and set accessories.
In focus
PV connector burnt out: Keep your distance and arrange for inspection.
A damaged PV connector should no longer be used. What documents will help the specialist company and why a photo alone is not sufficient for a reliable root cause analysis.
Buying a solar cable window feed-through: What documents you need before ordering
A flat design and compatible connectors are not enough. This checklist will help you clarify cable specifications, connection combinations, and installation location before purchasing a PV window feed-through.
Balcony power plant on the roof terrace: Check railings, flat roof, wind load and shading
What needs to be clarified before installing a balcony power plant on a roof terrace: A balcony power plant on a roof terrace requires a mounting system suitable for the building and the module. A railing...
Solarbank Expanding to 4 or STREAM 5000: Planning storage requirements and EV charging times
How much additional capacity suits your everyday life? Check charging windows, household needs, and wallbox availability separately.