The current shop ratings are loaded directly from the official rating source.
Open reviews at Trusted Shops- 1,6 kWh storage capacity in the set– Size of the offered storage configuration
- 1.600 Wh storage– Solarbank 2 E1600 AC
- 4 × 250 W solar panels– 1000 Wp flexible RENEPV V3.0
- 2 × 600 W PV input– 16–60 V · 16 A per MPPT
- 1 × Anker SOLIX solar bank 2 E1600 AC (SKU 10001)
- 1 × Anker SOLIX Smart Meter (SKU 10101)
- 4× RENEPV RFMM10NH6-250 flexible 250W PV module, total 1000Wp
ANKER SOLIX · FLEXIBLE STORAGE SET
Anker AC flexible set 1,6 kWh 4 × 250W flexible solar panels
Standard shipping (2-4 working days)
The stated delivery time is an estimate based on available goods. Shipping is handled by a freight carrier. Weekends, holidays, and scheduling requirements may delay delivery.
- Storage capacity in the set
- 1,6 kWh
- Size of the offered storage configuration
- Storage
- 1.600 Wh
- Solarbank 2 E1600 AC
- Solar Panels
- 4 × 250 W
- 1000 Wp flexible RENEPV V3.0
- PV input
- 2 × 600 W
- 16–60 V · 16 A per MPPT
Pay securely and easily
Up to 30 years guarantee
Enjoy maximum security: Up to 30-year warranty on high-performance modules, 10–12-year product warranty on inverters, and 10 years on battery storage systems (with a 15-year lifespan). For other products, please refer to the specific details in the respective product documentation.
30 day returns
Orders from Mini Power can be returned within 30 days of receipt, provided the return conditions are met. Your statutory right of withdrawal remains unaffected.
View the right of withdrawal24/7 customer support
You can contact us 7 days a week, 24 hours a day. We will respond as quickly as possible within the applicable service hours; however, an immediate 24/7 response is not guaranteed.
Contact serviceDynamic delivery forecastDelivery time
Standard shipping (2-4 working days)
The information provided is an estimate based on the selected shipping method. The final price displayed at checkout is binding.Estimate · binding at checkoutReal customer reviews of Mini Power
Mini Power · Product Information
Product description
The Anker SOLIX solar bank 2 E1600 AC set with 4× RENEPV V3.0 250W flex modules It combines a 1.600 Wh AC storage system, a smart meter, and 1000 W of module power. The new modules are designated RFMM10NH6-250. The scope of delivery and module data have been completely updated; electrical planning must be carried out in accordance with the limit values of both manufacturers and the intended wiring configuration.
Mini Power / New Power GmbH has been operating as a [company name] since 2025. Anker SOLIX Authorized Retailer certified. Proof is in the official Anker SOLIX Dealer Overview visible.
Delivery
1 × Anker SOLIX Smart Meter (SKU 10101)
4× RENEPV RFMM10NH6-250 flexible 250W PV module, total 1000Wp
1 × Anker SOLIX Schuko connection cable, 5 m
2× PV-Y parallel connectors
1× MC4 mounting tool
2x L-brackets and 2x cable organizers
Mounting hardware for the four flexible modules as per set scope
Produktvorteile
-- 1000 W updated module power: Four modules, each with 250 W, result in the module output specified in the set, which is uniformly documented.
-- Unique model assignment: The RFMM10NH6-250 is specified uniformly in terms of scope of delivery, datasheet and technical specifications.
-- 1.600 Wh AC storage: Storage capacity and PV module power remain transparent as separate quantities.
-- Smart meter included: The confirmed set includes the Anker SOLIX Smart Meter.
Compatibility
The set configuration is not a blanket approval for every wiring configuration or installation situation. Before commissioning, the MPP voltage, MPP current, open-circuit voltage, short-circuit current, number of inputs, current and power limits, and connectors must be checked against the documentation of the storage or inverter manufacturer and the RENEPV datasheet.
Technical information
-- PV inputs: 2 MPPT, each with a maximum output of 600 W
-- PV voltage range: 16–60 V
-- Maximum input current: 16 A per MPPT
-- AC output to the mains: up to 800 W
-- Off-grid output: up to 1.200 W
-- Maximum AC charging input: 2.000 W
-- Storage protection rating: IP65
-- Communication: WLAN and Bluetooth
-- RENEPV modules in a set: 4 × 250 W = 1000 W
-- Model: RFMM10NH6-250
-- Power tolerance: 0 to +5 W
-- Module efficiency: 21,4%
-- Vmp/Imp: 36,98V/6,76A
-- Voc / Isc: 43,35V ±3% / 7,30A ±3%
-- Dimensions per module: 1.159 × 1.009 × 2,5 mm
-- Weight per module: 4,3 kg ±3%
-- Construction: PET front and back layers, black backing
-- Junction box: IP67
-- PV cable: 4,0 mm²
-- Connectors: MC4-compatible, IP67
-- Operating temperature: −20 to +65 °C
-- Maximum series fuse: 15 A
-- Maximum system voltage: 1.500 V DC
-- Warranty according to data sheet: 5-year product warranty and 25-year performance warranty
RENEPV RFMM10NH6-250 Datasheet (PDF, English)
Matching accessories and related products
Why Mini Power
At Mini Power, in Set with 4× RENEPV V3.0 250W flex modules Storage system or microinverter, 1000 W module power, and accessories are shown separately. The current manufacturer's datasheet is linked directly; the confirmed scope of delivery is listed completely and in the original order. Since the electrical limits of both product groups must be tested together, the page does not contain a general compatibility guarantee or freely transferable wiring recommendations. This ensures that product selection remains transparent and technically comprehensible.
Frequently asked questions
-- What module power output does the updated set contain?
Included are 4 RENEPV modules, each with 250 W, for a total nominal power of 1000 W.
-- What fasteners or connecting parts are included?
Included are only the fastening or connecting parts listed in the scope of delivery, in the quantity specified therein.
Is electrical compatibility automatically guaranteed?
No. The electrical limits and the specific wiring must be checked against both manufacturers' documentation before commissioning.
Savings potential with complete set
Product values from your selection; please check example and household values.
Non-binding estimate.
Own performance or capacity: Adjust investment. Reset loads product values.
Mains output only: no charging or island output power.
Further assumptionsFurther assumptions
Loading estimate.
Fill in all fields and check the value ranges.
Savings for the overall system
estimated in the 1st year
Average per month
Self-consumption + feed-in tariff. Enter all acquisition costs for amortization.
Non-binding estimate.
all results
- PV generation
- kWh/year
- ownconsumption
- kWh/year
- Amortization
- years
- Gesamtinvestition
Self-consumption rate · entire system:
Average savings per year · 20 years
Average per monthSavings over 20 years
Less investmentChange in electricity prices / Decline in revenue: / .
This is how the estimate is generated.
PV generation before storage losses and AC limitation. Model basis for northern, central, and southern Germany: 920 / 1.020 / 1.150 kWh per kWp per year, adjusted for orientation, tilt, and shading. Season, daylight, and synthetic weather sequences distribute generation over 8.760 hours. Module power limits hourly peaks. For energy balancing, each hour is evenly divided into four quarter-hours. Measured weather data is not used.
A reference load profile derived from measurement data maps consumption over 35.040 quarter-hours and includes the peak loads. Day and night values are scaled separately to your annual consumption and the selected daytime period (08:00 AM–18:00 PM). Solar power first covers current demand, and stored energy covers the remaining demand. AC and charging power limit the energy every 15 minutes. Self-consumption only counts energy actually delivered to the household. All comparisons use the same weather and consumption profiles.
Mini Power calculation assumption: Self-consumption × 1,20 (+20%). The planning scenario is limited by PV generation, annual consumption, and the AC output; it is not a measured efficiency increase or yield guarantee.
Source of the reference load profile, primary data from CoSSMic / ISC Konstanz: Open Power System Data (2020), Household Data, 2020-04-15 · CC BY 4.0 LicenseProcessing: Household residential5, year 2017; cumulative meter readings converted into 15-minute consumption and scaled to annual consumption and daily share. Time base: fixed Central European Time (UTC+1). A reference household, not a measurement of your consumption.
Assumptions: 90% of the nominal capacity is usable; charging and discharging together achieve 90% efficiency. The storage system starts empty. Residual energy is retained across daily and annual limits, but only counts as savings when used. With DC coupling, excess PV power can charge before the AC limit is reached; with AC coupling, PV power is first limited to the input AC power. Direct consumption, storage discharge, and grid feed-in share this AC limit. No grid charging or feed-in from the storage system.
Entire system, first year: Value of self-consumed solar power at the set electricity price plus compensation for the exported surplus.
For all comparisons, yield and usage are recalculated in each of the 20 years. The annual PV yield decreases linearly with the set module aging, and the electricity price changes annually with a compounding effect. The feed-in tariff remains constant. The total savings add up all annual values, including negative values; the average annual savings is this sum divided by 20. The net value subtracts the investment, including additional costs. Amortization is achieved when the cumulative savings cover this investment. The point in time within a year is linearly interpolated.
The single AC input is a common model limitation; separate PV and battery inverters require a more detailed calculation. Without a separate charging power input, only available PV power and free storage capacity limit charging. The scaled reference profile of a household and synthetic PV weather values do not replace measurements of your system. Shorter peak loads (less than 15 minutes), battery aging, standby consumption, control systems, installation losses, and special load profiles for heat pumps or electric vehicles are not fully represented. Replacement purchases, maintenance, financing, and depreciation are not included. Higher AC power or larger storage capacities only increase savings if there is a usable surplus and corresponding consumption. Savings are not guaranteed.
Model estimate, not a guarantee of return. Monthly value = annual average; seasonal fluctuations.
Variants
Datasheet & Instructions
Verified product-related documents and instructions.
Technical information
Experience that creates trust
Why Mini Power
Mini Power helps you choose balcony power plants, storage systems, solar panels, and suitable accessories. Product information, scope of delivery, and compatibility are clearly presented so you can select a system that suits your location and energy needs. If you have any questions, you can contact us directly at info@miniminipower.com.
Start your own energy transition with Mini Power.
How are four modules connected to two MPPTs?
Are smart meters and Schuko cables included?
What are the PV input and AC grid output values?
What is included in the delivery of Anker Does the AC flexible set (1,6 kWh, 4 x 250W flexible solar panels included) include?
The included package contains: 1× Anker SOLIX solar bank 2 E1600 AC (SKU 10001); 1× Anker SOLIX Smart Meter (SKU 10101); 4× RENEPV RFMM10NH6-250 flexible 250W PV module, total 1000Wp; 1× Anker SOLIX Schuko connection cable, 5 m; 2× PV-Y parallel connectors; 1× MC4 mounting tool; 2× L-brackets and 2× cable organizers; mounting hardware for the four flexible modules as per set contents. The selected variant is decisive.
Where can I find the datasheet and instructions for Anker AC flexible set 1,6 kWh 4 × 250W flexible solar modules?
Available manufacturer documentation for the product can be found on this page in the "Datasheet & Instructions" section.
What components are included in the set of Anker Does the AC flexible set (1,6 kWh, 4 x 250W flexible solar panels included) include?
The decisive factor is the complete scope of delivery of the selected variant; modules, inverters, cables, plugs and mounting brackets must be checked separately.
What feed-in power and inverter configuration apply?
The decisive factors are the confirmed AC output power, the selected device configuration, and the specifications applicable to the connection.
STORAGE FINDER & COMPARISON
Is this set the right storage solution for you?
Compare storage technology and expandability independent of modules, mounting material and set accessories.
- 9 short questions
- 800 VA separately
- Price per kWh
In focus
PV connector burnt out: Keep your distance and arrange for inspection.
A damaged PV connector should no longer be used. What documents will help the specialist company and why a photo alone is not sufficient for a reliable root cause analysis.
Buying a solar cable window feed-through: What documents you need before ordering
A flat design and compatible connectors are not enough. This checklist will help you clarify cable specifications, connection combinations, and installation location before purchasing a PV window feed-through.
Balcony power plant on the roof terrace: Check railings, flat roof, wind load and shading
What needs to be clarified before installing a balcony power plant on a roof terrace: A balcony power plant on a roof terrace requires a mounting system suitable for the building and the module. A railing...
Expanding Solarbank 4 or STREAM 5000: Planning storage requirements and electric car charging times
How much additional capacity suits your everyday life? Check charging windows, household needs, and wallbox availability separately.